Example No. D12 Park Trailer (See 552.47)

A park trailer floor is 40 ft. by 10 ft. and has two small appliance circuits; a 1000-VA, 240-V heater; a 200-VA, 120-V exhaust fan; a 400-VA, 120-V dishwasher; and a 7000-VA electric range.

Lighting and Small Appliance Load

Lighting (40 x 10 x 3 VA per ft.2)

1200 VA

Small appliance (1500 VA x 2 circuits)

3000 VA

Laundry (1500 VA x 1 circuit)

1500 VA

Subtotal

5700 VA

First 3000 VA at 100%

3000 VA

Remainder (5700 VA - 3000 VA = 2700 VA) at 35%

945 VA

Total

3945 VA

 
 

Amperes per Leg

 

Leg A

Leg B

Lighting and appliances

16.44

16.44

Heater (1000 VA ÷ 240 V)

4.20

4.20

Fan (200 VA x 125% ÷ 120 V)

2.08

Dishwasher (400 VA ÷ 120 V)

3.3

Range (7000 VA x 0.8 ÷ 240 V)

23.30

23.30

Total amperes per leg

46.02

47.24

Based on the higher current calculated for either leg, a minimum 50-A supply cord would be required.