System Monitor in Windows 2000 extends the functionality provided by Performance Monitor, which shipped in Microsoft® Windows® NT versions 4.0 and Windows 3.51. Features of System Monitor include the following:
For information about logging and alert capabilities of the Performance console, see "Performance Logs and Alerts" later in this chapter. Windows NT 4.0 Performance Monitor is provided under the name Perfmon4.exe on the Windows 2000 Resource Kit companion CD. Typing perfmon.exe at the command prompt causes the system to launch System Monitor, not Performance Monitor.
If you are running Windows 2000 Professional, you can start the Performance console as follows:
When you start the Performance console, a blank System Monitor graph appears. Performance Logs and Alerts appears beneath System Monitor in the console tree, as shown in Figure 5.2.
Enlarge figure
Figure 5.2 Performance Console
The following section describes the user interface for System Monitor and provides tips on how to use it.
With System Monitor you can create graphs, bar charts (histograms), and text reports of performance counter data. System Monitor is designed for short-term viewing of data, troubleshooting, and diagnosis.
The System Monitor display consists of the following elements:
You can configure System Monitor using either the toolbar or a shortcut menu. Using the shortcut menu offers more control and flexibility in configuring the display. The following sections describe these different configuration methods. To see procedures and a brief overview of System Monitor, click Help on the System Monitor toolbar.
The toolbar is displayed by default. Using the toolbar, you can configure the following options:
Figure 5.3 shows the different display options.
Enlarge figure
Enlarge figure
Enlarge figure
Figure 5.3 Display Type Options for System Monitor
Histograms and reports are useful for simplifying graphs with multiple counters. However, they display only a single value, so they are recommended only when you are charting current activity and watching the graphs as they change. When you are reviewing data logged over time, line graphs are much more informative so that trends can be identified.
Enlarge figure
Figure 5.4 Add Counters Dialog Box
When you right-click the System Monitor display, a shortcut menu appears with the following options:
Enlarge figure
Figure 5.5 General Tab
Many properties can be configured from the toolbar, but some are only configurable using System Monitor Properties. The following table lists property tabs alphabetically by name, along with the attributes they control.
Table 5.2 System Monitor Properties
Use this tab | To add or change this |
---|---|
Colors | Background color of results pane surrounding the chart area, color of chart data-display area. You can choose each color from a palette (in the Property Name list box) or you can base the colors on system colors (screen elements) defined using the Display icon in Control Panel. When using the palette, note the following:
|
Grid color, timer bar color. | |
Data | Color, width, style, or chart line. Notice that defining a nondefault line width limits the line styles that are available. Styles can be selected only when you are using the default line width. |
Scale of counter data values. Counter values can be scaled exponentially from .0000001 to 1000000. You might want to adjust the counter scale settings to enhance the visibility of counter data in the chart. Changing the scale does not affect the statistics displayed in the value bar. | |
Objects, counters, and instances. | |
Fonts | Font type, size, and style. |
General | View type: chart, histogram, or report. |
Update frequency and manual or periodic sampling. | |
Histogram or report value type (choose between minimum, maximum, average values for the one displayed in a report view). Using report value types other than Current when monitoring real-time data incurs substantial overhead because of the need to make calculations across all samples for each value displayed. | |
Display of counter legend. | |
Display of last, minimum, and maximum values for a selected counter (the value bar). | |
Border style, appearance of the entire control. You can include or omit a border, or configure three-dimensional or flat effects for the window. | |
Display of toolbar. | |
Display of instance indexes (for monitoring multiple instances of a counter). The first instance (instance number 0) displays no index; System Monitor numbers subsequent instances starting with 1. | |
Graph | Title of graph. |
Label on value axis, vertical or horizontal grid lines, and upper and lower limits of graph axes. | |
Source | Source of data displayed: current data input to the graph, current or archived data input from a log. |
Time range for a log and view time range. |
Windows 2000 Server online Help for System Monitor explains how to perform common tasks. The following list supplements the information provided in online Help to enable you to use System Monitor more effectively.
Important
Monitoring large numbers of counters can incur a high amount of overhead, even to the point of making the system unresponsive to keyboard or mouse input. To reduce this burden, display data in report view when collecting from large numbers of counters or direct data to a binary log, and view the data in System Monitor as it is being written to the log.
perfmon.exe settings_file_name
When you open one of these settings files, the system temporarily converts the file for use with System Monitor but discards the converted version after the console starts. If you want to save the settings file for permanent use with System Monitor, type the following command:
perfmon.exe /HTMLFILE:new_file_name settings_file_name
© 1985-2000 Microsoft Corporation. All rights reserved.