One issue that complicates error handling is the fact that system administration scripts typically make use of COM objects. If an error occurs with the COM object itself, VBScript will be aware of the error. However, VBScript might have no knowledge of what actually caused the error. For example, in the following script, WMI attempts to bind to a nonexistent printer named TestPrinter. Not surprisingly, this raises an error. You might expect, therefore, to be able to trap the error number and description and echo that to the screen:

On Error Resume Next Set Test = GetObject _     ("Winmgmts:root\cimv2:Win32_Printer.Name='TestPrinter'") Wscript.Echo Err.Number & VbTab & Err.Description 

When the script runs, however, you get neither a standard four-digit VBScript error number nor any error description. Instead, you get the cryptic message box shown in Figure 2.23.

Figure 2.23   COM Object Error Number and Description

COM Object Error Number and Description

The problem is that the error occurred within WMI, and the error details are not available to VBScript. VBScript receives notice that an error occurred, and in most scripts that type of notice might be sufficient. In other scripts, however, or when you are developing and debugging a new script, you might find detailed error information much more useful.

Many COM objects provide their own mechanisms for trapping error information. For example, WMI allows you to create an error object, SWbemLastError, and then retrieve the following information:

  • Method being called when the error occurred.
  • Parameter responsible for generating the error.
  • Name of the WMI provider where the error occurred.

The following script uses the SWbemLastError object to retrieve error information from within WMI and then display that information in a message box.

On Error Resume Next Set Test = GetObject _     ("Winmgmts:root\cimv2:Win32_Printer.Name='TestPrinter'") Set WMI_Error = CreateObject("WbemScripting.SwbemLastError") Wscript.Echo WMI_Error.Operation & VbTab & _     WMI_Error.ParameterInfo & VbTab & WMI_Error.ProviderName 

When the preceding script runs, the message box in Figure 2.24 appears.

Figure 2.24   Message Box Using SWbemLastError

Message Box Using SWbemLastError

When working with SWbemLastError, you must create the error object following the line of code where you believe an error could occur. For example, the following script will not return any error information because the SWbemLastError object was created before the error occurred:

On Error Resume Next Set WMI_Error = CreateObject("WbemScripting.SwbemLastError") Set Test = GetObject _     ("Winmgmts:root\cimv2:Win32_Printer.Name='TestPrinter'") Wscript.Echo WMI_Error.Operation & VbTab & _     WMI_Error.ParameterInfo & VbTab & WMI_Error.ProviderName 

send us your feedback Send us your feedback « Previous | Next »   


Microsoft Windows 2000 Scripting Guide(c) Automating System Administration 2003
Microsoft Windows 2000 Scripting Guide(c) Automating System Administration 2003
ISBN: N/A
EAN: N/A
Year: 2004
Pages: 635

flylib.com © 2008-2017.
If you may any questions please contact us: flylib@qtcs.net