Chapter 13 Learning Check

 < Day Day Up > 

1:

RAID ADG offers higher fault tolerance than RAID 5.

  • True

  • False

A1:

Answer: True

2:

What is the maximum number of drives recommended by HP for a RAID 5 implementation?

  1. 6

  2. 12

  3. 14

  4. 56

A2:

Answer: C

3:

What is the recommended maximum number of drives per array for a RAID ADG implementation?

  1. 6

  2. 12

  3. 14

  4. 56

A3:

Answer: D

4:

Which array utility executes out of the option ROM that is located on an array controller, and is designed for situations that have minimal configuration requirements?

  1. Array Diagnostic Utility (ADU)

  2. Array Configuration Utility (ACU)

  3. Array Configuration Utility XE (ACU XE)

  4. Option ROM Configuration for Arrays (ORCA)

A4:

Answer: D

5:

What is a potential disadvantage of setting a high rebuild priority when an online spare drive is implemented?

A5:

Answer: Selecting a high rebuild priority results in reduced server performance while the rebuild is in progress.

6:

Which of the following LED statuses indicate that a drive has failed?

  1. On

  2. Blinking

  3. Off

  4. Blinking amber

A6:

Answer: D

     < Day Day Up > 


    HP ProLiant Servers AIS. Official Study Guide and Desk Reference