Microsoft® Windows® 2000 Scripting Guide
« Previous | Next »
The default WMI settings are adequate for most computers and most purposes. Under special circumstances, however, you might want to modify the WMI settings on a computer or a group of computers.
For example, a developer might want to configure WMI to log all errors for the purpose of collecting information that could help in debugging applications that use WMI. A system administrator might want to change the default namespace on the company's DNS servers from root\cimv2 to root\MicrosoftDNS. Using a script to change settings such as these is much faster than visiting each computer and manually reconfiguring the WMI service.
You can use the Win32_WMISetting class to reconfigure many of the WMI properties on a computer. Several of the configurable WMI settings are shown in Table 8.13.
Table 8.13 Configurable WMI Settings in the Win32_WMISetting Class
Property | Description |
---|---|
ASPScriptDefaultNamespace | Default script namespace. The default is root\cimv2. You must specify the entire namespace path, including root. |
BackupInterval | Length of time that will elapse between backups of the WMI database. The default is 30 minutes. |
EnableEvents | Boolean value indicating whether the WMI event subsystem is enabled. By default, EnableEvents is set to True. |
HighThresholdOnClientObjects | Maximum rate at which provider-created objects can be delivered to clients. The default value is 20,000,000 objects per second. |
HighThresholdOnEvents | Maximum rate at which events are to be delivered to clients. The default value is 2,000,000 event objects per second. |
LoggingDirectory | Directory path to the WMI system log files. The default is systemroot\WBEM\Logs. |
LoggingLevel | Indicates whether event logging is enabled and the verbosity level of logging used. By default, logging is disabled (set to 0). Values include: 0 No logging 1 Error logging 2 Verbose error logging |
LowThresholdOnClientObjects | Rate at which WMI starts to slow the creation of new objects created for clients. The default value is 10,000,000 objects per second. |
LowThresholdOnEvents | Rate at which WMI starts to slow the delivery of new events. The default value is 1,000,000 event objects per second. |
MaxLogFileSize | Maximum size of the log files produced by the WMI service. The default value is 65536 KB. |
MaxWaitOnClientObjects | Amount of time a newly created object waits to be used by the client before it is discarded and an error value is returned. The default value is 60,000 milliseconds (60 seconds). |
MaxWaitOnEvents | Amount of time for which an event sent to a client is queued before being discarded. The default value is 2,000 milliseconds (2 seconds). |
Listing 8.11 contains a script that configures WMI settings on a computer. To carry out this task the script must perform the following steps:
Listing 8.11 Configuring WMI Settings
|
|
Send us your feedback | « Previous | Next » |